产品中心 药物筛选试剂盒 UniOne®TR-FRET

UniOne® TR-FRET Human CDK4/CRBN PROTAC Binding Kit

价格 4,380.00 供应商现货 : 3-5个工作日
货号 UA086136
规格
数量
收藏 分享

产品介绍 评论(0)

背景介绍
  • ASSAY PRINCIPLE

    The kit is based on homogeneous time-resolved fluorescence technology (TR-FRET) technology,which is used to assess the molecular-mediated interaction between the DDB1/CRBN complex and CDK4/Cyclin D3 complex (CDK4). This method provides a high-throughput approach to detect the small molecules capable of mediating the interaction between the DDB1/CRBN complex and CDK4/Cyclin D3 complex simply and rapidly .

    As shown in the figure below, the interaction between DDB1/CRBN and CDK4/Cyclin D3 was detected by an Eu-labeled anti-Tag1 antibody (TR-FRET donor) and an Ac-labeled anti-Tag2 antibody (TR-FRET receptor). Since the molecular adhesive BSJ-03-204 mediates the interaction between DDB1/CRBN and CDK4/Cyclin D3, the donor antibody is in close proximity to the receptor antibody. Excitation of the donor antibody triggers fluorescence resonance energy transfer (FRET) to the receptor antibody, resulting in specific emission of a signal at a wavelength of 665 nm from the receptor antibody. This specific signal is proportional to the degree of interaction between BSJ-03-204, DDB1/CRBN and CDK4/Cyclin D3. This homogeneous assay is simple to perform and requires no washing steps.

产品规格
  • 来源

    Human
  • 储存条件

    -80℃

产品组分
  • 【Composition and Storage Conditions】

    Composition

    concentration

    100T

    500T

    2500T

    10000T

    Storage

    Tag1-CRBN protein

    100×

    5μL

    20μL

    100μL

    400μL

    -80℃

    Tag2-CDK4 protein

    126×

    5μL

    16μL

    80μL

    320μL

    -80℃

    BSJ-03-204

    1 mM

    5μL

    10μL

    50μL

    200μL

    -80℃

    Anti-Tag1 Eu antibody

    50×

    10μL

    50μL

    250μL

    1000μL

    -80℃

    Anti-Tag2 Ac antibody

    100×

    5μL

    25μL

    125μL

    500μL

    -80℃

    Detection buffer

    3mL

    15mL

    75mL

    300mL

    -80℃


    Note: Aliquot into appropriate volumes, store at the recommended temperature and avoid repeated freeze-thaw cycle.

操作步骤
  • 【Process and Operations】

    1、Reagent Preparation

    1.1 Compositions equilibration

    Before use, dissolve all reagents at room temperature (allow at least 30 minutes for temperature equilibration). For the 384-well plate assay, use 20 μL of reaction mixture (the reagent quantities are listed in the table below). Calculate the required volume prior to preparation accordingly. The following preparation steps are provided for reference only, using a 500-well plate as an example.

    Table 1. Reagent Preparation

    Composition

    配置

    μL/well

    Tag1-CRBN protein

    Take 20 μL of the 100× Tag1-CRBN protein stock solution, add 1.98 mL of Detection buffer to dilute it to 1× concentration, and mix thoroughly for later use.

    4

    Tag2-CDK4 protein

    Take 16 μL of 126× Tag2-CDK4 protein stock solution, add it to 2 mL of Detection buffer to dilute to 1× concentration, and mix thoroughly for later use.

    4

    Antibody Mix

    Take 50 μL of the 50× Anti-Tag1 Eu antibody stock solution, add 2450 μL of Detection buffer to dilute to 2.5 mL, and mix thoroughly; take 25 μL of the 100×Anti-Tag2 Ac antibody stock solution, add 2475 μL μL of Detection buffer to dilute to 2.5 mL, and mix thoroughly; combine the two solutions in a 1:1 ratio to obtain the Antibody Mix.

    10


    1.2 Gradient dilution of the sample

    BSJ-03-204 as an example, the dilution solution is Detection buffer. To minimize interference from matrix effects, it is recommended to use a solution with the same matrix composition as the sample being tested; additionally, the sample concentration should be adjusted according to its actual situation.

    Table 2. BSJ-03-204 gradient dilution(Adjust according to the actual situation)

    BSJ-03-204 final concentration(nM)

    BSJ-03-204 preparation concentration(nM)

    Dilution

    2000

    20000

    2μL 1mM BSJ-03-204 +98μL 1× Detection buffer

    1000

    10000

    30μL +30μL Detection buffer

    500

    5000

    30μL +30μL Detection buffer

    250

    2500

    30μL +30μL Detection buffer

    125

    1250

    30μL +30μL Detection buffer

    62.5

    625

    30μL +30μL Detection buffer

    31.25

    312.5

    30μL +30μL Detection buffer

    15.625

    156.25

    30μL +30μL Detection buffer

    7.8125

    78.125

    30μL +30μL Detection buffer

    3.90625

    39.0625

    30μL +30μL Detection buffer

    Blank

    0

    0

    30μL Detection buffer


    2、Sample and control

    2.1 Sample:Add 4 μL of Tag1-CRBN protein working solution, 4 μL of Tag2-CDK4 protein working solution, 2 μL of the gradient-diluted sample , and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

    2.2 BSJ-03-204: 4 μL of Tag1-CRBN protein working solution, 4 μL of Tag2-CDK4 protein working solution, 2 μL of gradient-diluted BSJ-03-204, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

    2.3 Blank:4 μL of Tag1-CRBN protein working solution, 4 μL of Tag2-CDK4 protein working solution, 2 μL of Detection buffer, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

    2.3 Negative control 10μL Detection buffer, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

    After adding all samples, centrifuge, seal with a cover membrane, and incubate at room temperature for 2 hours.

    Table 3. Sample and control spotting process

    BSJ-03-204

    Sample

    Blank

    Negative control(NC)

    2μL

    gradient-diluted BSJ-03-204

    2μL

    gradient-diluted sample

    2μL

    Detection buffer

    10μL Detection buffer

    and 10μL Antibody Mix

    4μL Tag1-CRBN protein

    4μL Tag2-CDK4 protein

    10μL Antibody Mix

    Seal the plate wells with a sealing film and incubate at room temperature more than 2 hours.


    3、Read Data

    The detection was performed on a TR-FRET microplate reader. The excitation wavelength was 320/340 nm, and the emission wavelengths at 620 nm and 665 nm were detected.

    【DATA REDUCTION 】

    1) Ratio

    Ratio = (665/620) ×10000

    2) Net signal

    Net signal = (Std-NC)/NC×100

    Std:the ratio of sample and control

    NC: the ratio of negative control

    3) CV(%)

    CV(%)= Standard Deviation/Mean Ratio × 100%

    Data Example

    The following data cannot replace experimental results obtained in experiments; they are provided solely for illustrative purposes, and outcomes may vary depending on the plate reader used.

    Note: Recommended microplate (384-well plate, white, shallow wells).

评论(0)