产品中心 ELISA试剂盒 OneStep ELISA 试剂盒
产品介绍 评论(0)
抗原名称
IgM免疫原
Recombinant Protein抗体类型
Recombinant mAb反应种属 ?
Ms纯化方式
Protein A储存条件
12 months from date of receipt / reconstitution, 2 to 8°C as supplied.
Precision
Intra-assay: 4.5%;
Inter-assay: 5.1%Sample type
Serum; EDTA plasma; Cell Culture SupernatantAssay type
Sandwich (quantitative)Sensitivity
0.046 ng/mLRange
0.078 ng/mL – 5 ng/mLRecovery
Serum (Balb/c): 114%
EDTA plasma (Balb/c): 107%
Cell Culture Supernatant: 98%Assay time
60 minutesSpecies reactivity
Ms
Mouse immunoglobulin M (IgM) is a crucial component of the humoral immune system and is the first antibody produced by B-cells in response to an antigenic challenge. It exists in two forms: a pentameric (19S) form found in serum and a monomeric (8S) form on the surface of lymphocytes. The IgM pentamer, which is the predominant form in circulation, consists of five monomeric units and has a molecular weight of approximately 900 kDa, while the hexameric form has a molecular weight of about 1050 kDa. Each monomer of IgM is composed of two heavy chains and two light chains, with the heavy chain having four constant domains (CH1-CH4) and the light chain having one constant domain (CL). The CH4 domain facilitates oligomerization, leading to the formation of penta- or hexamers, and these oligomers are covalently linked via disulfide bonds, resembling a snowflake structure. A joining (J) chain, a 15 kDa polypeptide, is essential for the secretion of IgM into mucosal areas.
ELISA
Standard Curve
Example of Mouse IgM standard curve in Assay Diluent A1. Plotted are the background-subtracted data.
This standard curve is provided for demonstration only.Spike Recovery
Recovery of Mouse IgM was assessed by spiking a 5 ng/mL standard into 0.00063% serum. Recovery of Mouse IgM was assessed by spiking a 5 ng/mL standard into 0.00063% EDTA-Plasma. Serial dilutions of the spiked sample were prepared, and the percent recovery was calculated for each dilution relative to the expected concentration.Dilution Linearity
The concentrations of Mouse IgM were measured and interpolated from the target standard curves and corrected for sample dilution.
The leftmost bar in the graph shows biological samples diluted in Assay Diluent to 0.0025% concentration. "undiluted" was defined as 0.0025% biological sample. The subsequent bars represent two-fold serial dilutions of this reference. The mean target concentration was determined to be 533.31 ug/mL in Balb/c Mouse serum.
The mean target concentration was determined to be 285.11 ug/mL in Balb/c Mouse Citrate-plasma.
The mean target concentration was determined to be 401.89 ug/mL in Balb/c Mouse EDTA-plasma.Dilution Linearity
The concentrations of Mouse IgM were measured and interpolated from the target standard curves and corrected for sample dilution.
The leftmost bar in the graph shows biological samples diluted in Assay Diluent to 0.005% concentration. "undiluted" was defined as 0.005% biological sample. The subsequent bars represent two-fold serial dilutions of this reference. The mean target concentration was determined to be 140.21 ug/mL in C57 Mouse serum.
The mean target concentration was determined to be 108.18 ug/mL in C57 Mouse Citrate-plasma.
The mean target concentration was determined to be 125.21 ug/mL in C57 Mouse Heparin-plasma.Dilution Linearity
The concentrations of Mouse IgM were measured and interpolated from the target standard curves and corrected for sample dilution.
The leftmost bar in the graph shows biological samples diluted in Assay Diluent to 0.005% concentration. "undiluted" was defined as 0.005% biological sample. The subsequent bars represent two-fold serial dilutions of this reference. The mean target concentration was determined to be 128.53 ug/mL in CD-1 Mouse serum.
The mean target concentration was determined to be 117.52 ug/mL in CD-1 Mouse EDTA-plasma.
The mean target concentration was determined to be 100.28 ug/mL in CD-1 Mouse Heparin-plasma.Intra-Assay Precision (Precision within an assay)
Three samples of known concentration were tested fifteen times on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays).
Three samples of known concentration were tested in separate assays to assess inter-assay precision. Assays were performed with at least three lots of components.Determination of Minimum Detectable Dose (MDD)
The MDD was determined using three independent lots of assay components. For each lot, 19 replicate measurements of the diluent (zero calibrator) were performed. The mean (AVERAGE) and standard deviation (STDEV) of the 19 replicates were calculated. The MDD for each lot was then calculated according to the following formula:
MDD = 2 × STDEV + AVERAGECross‑reactivity
Tests for the specificity of various serum and proteins showed no cross-reactivity.HOOK Effect Threshold
The upper limit of the HOOK effect was established at 100× the highest calibrator concentration (equivalent to a 2-log10 increase). No HOOK effect was observed below this threshold, confirming that samples within this concentration range yield reliable quantitative results without signal depression.Protocol Diagram







评论(0)