产品中心 流式试剂&相关 流式抗体

所有图片(1/1)

Biotin Mouse Anti-Human HLA-B27 Antibody (HLA-ABC-m3)

HLA class I histocompatibility antigen,B alpha chain,Human leukocyte antigen B (HLA-B),HLAB,HLA-B

价格 650.00 供应商现货 : 3-5个工作日
货号 S0B8545
规格
数量
收藏 分享

产品介绍 评论(0)

产品规格
  • 宿主来源

    Mouse
  • 抗原名称

    HLA-B27
  • 分子别名

    HLA class I histocompatibility antigen, B alpha chain; Human leukocyte antigen B (HLA-B); HLAB; HLA-B
  • 细胞定位

    Cell membrane, Endoplasmic reticulum membrane
  • Accession

    P03989
  • 克隆号

    HLA-ABC-m3
  • 抗体类型

    Mouse mAb
  • 抗体同种型

    IgG2a
  • 反应种属 ?

    Hu
  • 阳性样本

    human peripheral blood leukocytes
  • 纯化方式

    Protein A
  • 浓度

    0.2 mg/ml
  • 标记

    Biotin
  • 性状

    Liquid
  • 缓冲体系

    PBS pH7.4, 0.03% Proclin 300

  • 储存条件

    12 months from date of receipt / reconstitution, 2 to 8 °C as supplied

  • 应用

    FCM

  • 稀释度

    应用 稀释度 推荐种属
    FCM 5μl per million cells in 100μl volume Hu
背景介绍
  • HLA-B27 is a highly polymorphic class I major histocompatibility complex (MHC-I) molecule expressed on virtually all nucleated cells that folds in the endoplasmic reticulum with β2-microglobulin to form a peptide-binding groove preferentially anchoring arginine at position 2, transports these peptides to the cell surface for surveillance by CD8⁺ cytotoxic T lymphocytes, and—through mechanisms still debated encompassing presentation of “arthritogenic” self or microbial peptides, heavy-chain misfolding that triggers endoplasmic-reticulum stress and autophagy, and aberrant homodimer formation that activates innate killer receptors—confers the strongest known genetic risk for the spondyloarthritis family (ankylosing spondylitis, reactive arthritis, psoriatic arthritis, juvenile enthesitis-related arthritis) and acute anterior uveitis while paradoxically protecting against several viral infections, with disease-associated subtypes such as B27:05 and B27:04 differing from non-associated or protective subtypes by only one or two amino acids lining the antigen-binding cleft that alter peptide repertoire and surface stability.

  • 流式分析

    • Flow cytometric analysis of Human HLA-B27 expression on human peripheral blood leukocytes. Human peripheral blood leukocytes were stained with SDT Biotin Mouse Anti- Human HLA-B27 antibody (Right panel) at 5 μl/test followed by Sav-PE. Total viable cells, as determined by Fixable Viability Dye 515 (S0D0013), were used for analysis. Flow cytometry and data analysis were performed using BD FACSymphony™ A1 and FlowJo™ software.

评论(0)