产品中心 流式试剂&相关 流式抗体

所有图片(1/1)

Alexa Fluor® 700 Rabbit Anti-Human CD4 Antibody (13B8.2)

T-cell surface glycoprotein CD4,T-cell surface antigen T4/Leu-3

价格 1,050.00 供应商现货 : 3-5个工作日
货号 S0B80393
规格
数量
收藏 分享

产品介绍 评论(0)

产品规格
  • 宿主来源

    Rabbit
  • 抗原名称

    CD4
  • 分子别名

    T-cell surface glycoprotein CD4; T-cell surface antigen T4/Leu-3
  • 细胞定位

    Cell membrane, Endoplasmic reticulum
  • Accession

    P01730
  • 克隆号

    13B8.2
  • 抗体类型

    Recombinant mAb
  • 抗体同种型

    IgG
  • 反应种属 ?

    Hu
  • 阳性样本

    Human PBMC
  • 纯化方式

    Protein A
  • 浓度

    0.1 mg/ml
  • 标记

    Alexa Fluor® 700
  • 性状

    Liquid
  • 缓冲体系

    PBS, 1% BSA, 0.3% Proclin 300

  • 储存条件

    12 months from date of receipt / reconstitution, 2 to 8 °C as supplied

  • 应用

    FCM

  • 稀释度

    应用 稀释度 推荐种属
    FCM 1μl per million cells in 100μl volume Hu
背景介绍
  • CD4 (cluster of differentiation 4) is a glycoprotein that serves as a co-receptor for the T-cell receptor (TCR). CD4 is found on the surface of immune cells such as helper T cells, monocytes, macrophages, and dendritic cells. CD4 is a co-receptor of the T cell receptor (TCR) and assists the latter in communicating with antigen-presenting cells. The TCR complex and CD4 bind to distinct regions of the antigen-presenting MHC class II molecule. The extracellular D1 domain of CD4 binds to the β2 region of MHC class II. The resulting close proximity between the TCR complex and CD4 allows the tyrosine kinase Lck bound to the cytoplasmic tail of CD4 to phosphorylate tyrosine residues of immunoreceptor tyrosine activation motifs (ITAMs) on the cytoplasmic domains of CD3 to amplify the signal generated by the TCR. CD4 continues to be expressed in most neoplasms derived from T helper cells. It is therefore possible to use CD4 immunohistochemistry on tissue biopsy samples to identify most forms of peripheral T cell lymphoma and related malignant conditions. The antigen has also been associated with a number of autoimmune diseases such as vitiligo and type I diabetes mellitus.

  • 流式分析

    • Flow cytometric analysis of CD4 expression on human PBMC (human peripheral blood mononuclear cell). Human PBMC were stained with Alexa Fluor® 488 Mouse Anti-Human CD3 Antibody and either Alexa Fluor® 700 Mouse IgG Isotype Control (left panel) or SDT Alexa Fluor® 700 Mouse Anti-Human CD4 Antibody (right panel) at 1 μl/test. Total viable cells, as determined by Fixable Viability Dye 452 (S0D0021), were used for analysis. Flow cytometry and data analysis were performed using Agilent NovoCyte Quanteon and FlowJo™ software.

评论(0)