产品中心 抗体 病理/IHC抗体

所有图片(1/9)

Carbonic Anhydrase 9 Recombinant Rabbit mAb (SDT-733-28)

Carbonate dehydratase IX,Carbonic anhydrase IX (CA-IX,CAIX),Membrane antigen MN,P54/58N,Renal cell carcinoma-associated antigen G250 (RCC-associated antigen G250),pMW1,CA9,G250,MN

价格 600.00 供应商现货 : 3-5个工作日
货号 S0B2289
规格
数量
收藏 分享

产品介绍 评论(0)

产品规格
  • 宿主来源

    Rabbit
  • 分子别名

    Carbonate dehydratase IX, Carbonic anhydrase IX (CA-IX; CAIX), Membrane antigen MN, P54/58N, Renal cell carcinoma-associated antigen G250 (RCC-associated antigen G250), pMW1, CA9, G250, MN
  • 免疫原

    Synthetic Peptide
  • 细胞定位

    Cell membrane
  • Accession

    Q16790
  • 克隆号

    SDT-733-28
  • 抗体类型

    Recombinant mAb
  • 抗体同种型

    IgG
  • 反应种属 ?

    Hu
  • 纯化方式

    Protein A
  • 浓度

    0.5 mg/ml
  • 标记

    Unconjugated
  • 性状

    Liquid
  • 缓冲体系

    PBS, 40% Glycerol, 0.05%BSA, 0.03% Proclin 300
  • 储存条件

    12 months from date of receipt / reconstitution, -20 °C as supplied

  • 应用

    IHC-P ?

    WB

  • 稀释度

    应用 稀释度
    WB 1:1000
    IHC-P 1:500
背景介绍
  • Carbonic anhydrase IX (CA9/CAIX) is an enzyme encoded by the CA9 gene. It is one of the 14 subtypes of carbonic anhydrase discovered by humans, a transmembrane dimer metalloenzyme with extracellular active sites that promote gastrointestinal acid secretion. CAIX is overexpressed in many types of cancers, including clear cell renal cell carcinoma (RCC), cervical cancer, breast cancer, and lung cancer. In these cancers, CAIX promotes tumor growth by enhancing tumor acidosis.

  • 免疫印迹

    • WB result of Carbonic Anhydrase 9 Rabbit mAb
      Primary antibody: Carbonic Anhydrase 9 Rabbit mAb at 1/1000 dilution
      Lane 1: HT-29 whole cell lysate 20 µg
      Secondary antibody: Goat Anti-Rabbit IgG, (H+L), HRP conjugated at 1/10000 dilution
      Predicted MW: 50 kDa
      Observed MW: 54, 58 kDa

  • 免疫组化

    • IHC shows positive staining in paraffin-embedded human stomach. Anti-Carbonic Anhydrase 9 antibody was used at 1/500 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • Negative control: IHC shows negative staining in paraffin-embedded human colon. Anti- Carbonic Anhydrase 9 antibody was used at 1/500 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human colon cancer. Anti-Carbonic Anhydrase 9 antibody was used at 1/500 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human bladder cancer. Anti-Carbonic Anhydrase 9 antibody was used at 1/500 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human gastric cancer. Anti-Carbonic Anhydrase 9 antibody was used at 1/500 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human ovarian cancer. Anti-Carbonic Anhydrase 9 antibody was used at 1/500 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human renal clear cell cancer. Anti-Carbonic Anhydrase 9 antibody was used at 1/500 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • Negative control: IHC shows negative staining in paraffin-embedded human chromophobe renal carcinoma. Anti- Carbonic Anhydrase 9 antibody was used at 1/500 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

评论(0)