产品中心 抗体 其他一抗

所有图片(1/9)

BAG3 Recombinant Rabbit mAb (S-1837-22)

BAG family molecular chaperone regulator 3,BAG-3,Bcl-2-associated athanogene 3,Bcl-2-binding protein Bis,Docking protein CAIR-1,BIS

价格 600.00 供应商现货 : 3-5个工作日
货号 S0B1266
规格
数量
收藏 分享

产品介绍 FAQs 评论(0)

产品规格
  • 宿主来源

    Rabbit
  • 抗原名称

    BAG3
  • 分子别名

    BAG family molecular chaperone regulator 3; BAG-3; Bcl-2-associated athanogene 3; Bcl-2-binding protein Bis; Docking protein CAIR-1; BIS
  • 免疫原

    Recombinant Protein
  • 细胞定位

    Cytoplasm, Nucleus
  • Accession

    O95817
  • 克隆号

    S-1837-22
  • 抗体类型

    Recombinant mAb
  • 抗体同种型

    IgG
  • 反应种属 ?

    Hu
  • 阳性样本

    HeLa, K562, 293T
  • 纯化方式

    Protein A
  • 浓度

    0.5 mg/ml
  • 标记

    Unconjugated
  • 性状

    Liquid
  • 缓冲体系

    PBS, 40% Glycerol, 0.05% BSA, 0.03% Proclin 300
  • 储存条件

    12 months from date of receipt / reconstitution, -20 °C as supplied

  • 应用

    IHC-P ?

    ICC ?

    WB

  • 稀释度

    应用 稀释度 推荐种属
    WB 1:1000 Hu
    IHC-P 1:250 Hu
    ICC 1:500 Hu
背景介绍
  • BAG3 protein, also known as Bcl2-associated athanogene 3, is a 575 amino acid multi-functional protein that is widely expressed across various tissues but is most abundant in cardiac muscle, skeletal muscle, the brain, and many cancers. It plays a crucial role in maintaining cellular homeostasis by supporting the autophagy of misfolded proteins and damaged organelles, inhibiting apoptosis, preserving mitochondrial homeostasis, and facilitating excitation-contraction coupling through the L-type calcium channel and the beta-adrenergic receptor. High levels of BAG3 are associated with resistance to chemotherapy in malignant cells, while both loss of function and gain of function variants are linked to cardiomyopathy. BAG3 is also characterized by its multiple protein-protein binding domains, which enable it to establish discrete intracellular micro-environments based on its specific responsibilities and locations within the cell. .

  • 免疫印迹

    • WB result of BAG3 Recombinant Rabbit mAb
      Primary antibody: BAG3 Recombinant Rabbit mAb at 1/1000 dilution
      Lane 1: HL-60 whole cell lysate 20 µg
      Lane 2: HeLa whole cell lysate 20 µg
      Lane 3: K562 whole cell lysate 20 µg
      Lane 4: 293T whole cell lysate 20 µg
      Negative control: HL-60 whole cell lysate
      Secondary antibody: Goat Anti-rabbit IgG, (H+L), HRP conjugated at 1/10000 dilution
      Predicted MW: 62 kDa
      Observed MW: 80 kDa

  • 免疫组化

    • IHC shows positive staining in paraffin-embedded human cerebral cortex. Anti-BAG3 antibody was used at 1/250 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human cardiac muscle. Anti-BAG3 antibody was used at 1/250 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human hepatocellular carcinoma. Anti-BAG3 antibody was used at 1/250 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human colon cancer. Anti-BAG3 antibody was used at 1/250 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human ovarian cancer. Anti-BAG3 antibody was used at 1/250 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

  • 免疫细胞化学

    • ICC shows positive staining in HeLa cells. Anti- BAG3 antibody was used at 1/500 dilution (Green) and incubated overnight at 4°C. Goat polyclonal Antibody to Rabbit IgG - H&L (Alexa Fluor® 488) was used as secondary antibody at 1/1000 dilution. The cells were fixed with 100% ice-cold methanol and permeabilized with 0.1% PBS-Triton X-100. Nuclei were counterstained with DAPI (Blue). Counterstain with tubulin (Red).

  • 组织表达图谱

    • Expression of BAG3 in human tissue.

    • Expression of BAG3 in tumor tissue.

FAQs

斯达特公司的抗体,可以回收利用几次?

我们一般不推荐客户回收利用抗体。 因为抗体使用之后缓冲体系已经发生改变,不同客户在回收抗体的保存条件上也会有差异,所以抗体回收使用效果无法保证。另外,我们对一批抗体回收验证测试,测试结果显示不同抗体可回收次数不同,一般效价越高的抗体,可重复使用的次数越多,客户可根据实验情况来确定

评论(0)