产品中心 抗体 其他一抗

所有图片(1/6)

Myosin light chain 3 Recombinant Rabbit mAb (S-664-75)

Cardiac myosin light chain 1,CMLC1,Myosin light chain 1,slow-twitch muscle B/ventricular isoform,MLC1SB,Ventricular myosin alkali light chain,Ventricular myosin light chain 1,VLCl,Ventricular/slow twitch myosin alkali light chain,MLC-lV/sb,MYL3

价格 600.00 供应商现货 : 3-5个工作日
货号 S0B0516
规格
数量
收藏 分享

产品介绍 FAQs 评论(0)

产品规格
  • 宿主来源

    Rabbit
  • 抗原名称

    Myosin light chain 3
  • 分子别名

    Cardiac myosin light chain 1, CMLC1, Myosin light chain 1, slow-twitch muscle B/ventricular isoform, MLC1SB, Ventricular myosin alkali light chain, Ventricular myosin light chain 1, VLCl, Ventricular/slow twitch myosin alkali light chain, MLC-lV/sb, MYL3
  • 免疫原

    Synthetic Peptide
  • 细胞定位

    Cytosol
  • Accession

    P08590
  • 克隆号

    S-664-75
  • 抗体类型

    Recombinant mAb
  • 抗体同种型

    IgG
  • 反应种属 ?

    Hu, Ms, Rt
  • 纯化方式

    Protein A
  • 浓度

    0.5 mg/ml
  • 标记

    Unconjugated
  • 性状

    Liquid
  • 缓冲体系

    PBS, 40% Glycerol, 0.05%BSA, 0.03% Proclin 300
  • 储存条件

    12 months from date of receipt / reconstitution, -20 °C as supplied

  • 应用

    IHC-P ?

    WB

  • 稀释度

    应用 稀释度 推荐种属
    WB 1:1000 Ms, Rt
    IHC-P 1:2000 Hu, Ms, Rt
背景介绍
  • Myosin essential light chain (ELC), ventricular/cardiac isoform is a protein that in humans is encoded by the MYL3 gene. This cardiac ventricular/slow skeletal ELC isoform is distinct from that expressed in fast skeletal muscle (MYL1) and cardiac atrial muscle (MYL4). Ventricular ELC is part of the myosin molecule and is important in modulating cardiac muscle contraction. Mutations in MYL3 have been identified as a cause of familial hypertrophic cardiomyopathy, and associated with a mid-left ventricular chamber type hypertrophy.

  • 免疫印迹

    • WB result of Myosin light chain 3 Rabbit mAb
      Primary antibody: Myosin light chain 3 Rabbit mAb at 1/1000 dilution
      Lane 1: mouse heart lysate 20 µg
      Lane 2: mouse skeletal muscle lysate 20 µg
      Secondary antibody: Goat Anti-Rabbit IgG, (H+L), HRP conjugated at 1/10000 dilution
      Predicted MW: 22 kDa
      Observed MW: 24 kDa

    • WB result of Myosin light chain 3 Rabbit mAb
      Primary antibody: Myosin light chain 3 Rabbit mAb at 1/1000 dilution
      Lane 1: rat heart lysate 5 µg
      Lane 2: rat skeletal muscle lysate 5 µg
      Secondary antibody: Goat Anti-Rabbit IgG, (H+L), HRP conjugated at 1/10000 dilution
      Predicted MW: 22 kDa
      Observed MW: 22 kDa

  • 免疫组化

    • IHC shows positive staining in paraffin-embedded human cardiac muscle. Anti-Myosin light chain 3 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human skeletal muscle. Anti-Myosin light chain 3 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded mouse cardiac muscle. Anti-Myosin light chain 3 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded rat cardiac muscle. Anti-Myosin light chain 3 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

FAQs

斯达特公司的抗体,可以回收利用几次?

我们一般不推荐客户回收利用抗体。 因为抗体使用之后缓冲体系已经发生改变,不同客户在回收抗体的保存条件上也会有差异,所以抗体回收使用效果无法保证。另外,我们对一批抗体回收验证测试,测试结果显示不同抗体可回收次数不同,一般效价越高的抗体,可重复使用的次数越多,客户可根据实验情况来确定

评论(0)