产品中心 抗体 其他一抗

所有图片(1/12)

MEK3 Recombinant Rabbit mAb (S-835-23)

Dual specificity mitogen-activated protein kinase kinase 3,MAP kinase kinase 3,MAPKK 3,MAPK/ERK kinase 3,SAPK kinase 2,SAPKK-2,SAPKK2,Stress-activated protein kinase kinase 2

价格 600.00 供应商现货 : 3-5个工作日
货号 S0B0503
规格
数量
收藏 分享

产品介绍 FAQs 评论(0)

产品规格
  • 宿主来源

    Rabbit
  • 分子别名

    Dual specificity mitogen-activated protein kinase kinase 3, MAP kinase kinase 3, MAPKK 3, MAPK/ERK kinase 3, SAPK kinase 2, SAPKK-2, SAPKK2, Stress-activated protein kinase kinase 2
  • 免疫原

    Recombinant Protein
  • 细胞定位

    Cytoplasm, Nucleus
  • Accession

    P46734
  • 克隆号

    S-835-23
  • 抗体类型

    Recombinant mAb
  • 抗体同种型

    IgG
  • 反应种属 ?

    Hu, Ms, Rt
  • 纯化方式

    Protein A
  • 浓度

    0.5 mg/ml
  • 标记

    Unconjugated
  • 性状

    Liquid
  • 缓冲体系

    PBS, 40% Glycerol, 0.05%BSA, 0.03% Proclin 300
  • 储存条件

    12 months from date of receipt / reconstitution, -20 °C as supplied

  • 应用

    ICFCM

    IHC-P ?

    ICC ?

    WB

    IP

  • 稀释度

    应用 稀释度 推荐种属
    WB 1:1000 Hu, Ms, Rt
    IP 1:50 Hu
    IHC-P 1:250 Hu, Ms
    ICC 1:500 Hu, Ms
    ICFCM 1:500 Ms
背景介绍
  • Dual specificity kinase. Is activated by cytokines and environmental stress in vivo. Catalyzes the concomitant phosphorylation of a threonine and a tyrosine residue in the MAP kinase p38. Part of a signaling cascade that begins with the activation of the adrenergic receptor ADRA1B and leads to the activation of MAPK14.

  • 免疫印迹

    • WB result of MEK3 Rabbit mAb
      Primary antibody: MEK3 Rabbit mAb at 1/1000 dilution
      Lane 1: HepG2 whole cell lysate 20 µg
      Lane 2: HeLa whole cell lysate 20 µg
      Lane 3: MCF7 whole cell lysate 20 µg
      Secondary antibody: Goat Anti-Rabbit IgG, (H+L), HRP conjugated at 1/10000 dilution
      Predicted MW: 39 kDa
      Observed MW: 36, 39 kDa
      (This blot was developed with high sensitivity substrate)

    • WB result of MEK3 Rabbit mAb
      Primary antibody: MEK3 Rabbit mAb at 1/1000 dilution
      Lane 1: NIH/3T3 whole cell lysate 20 µg
      Secondary antibody: Goat Anti-Rabbit IgG, (H+L), HRP conjugated at 1/10000 dilution
      Predicted MW: 39 kDa
      Observed MW: 36, 39 kDa
      (This blot was developed with high sensitivity substrate)

    • WB result of MEK3 Rabbit mAb
      Primary antibody: MEK3 Rabbit mAb at 1/1000 dilution
      Lane 1: C6 whole cell lysate 20 µg
      Secondary antibody: Goat Anti-Rabbit IgG, (H+L), HRP conjugated at 1/10000 dilution
      Predicted MW: 39 kDa
      Observed MW: 39 kDa
      (This blot was developed with high sensitivity substrate)

  • 流式分析

    • Flow cytometric analysis of 4% PFA fixed 90% methanol permeabilized NIH/3T3 (Mouse embryonic fibroblast) cells labelling MEK3 antibody at 1/500 dilution (0.1 μg)/ (Red) compared with a Rabbit monoclonal IgG (Black) isotype control and an unlabelled control (cells without incubation with primary antibody and secondary antibody) (Blue). Goat Anti - Rabbit IgG Alexa Fluor® 488 was used as the secondary antibody.

  • 免疫沉淀

    • MEK3 Rabbit mAb at 1/50 dilution (1 µg) immunoprecipitating MEK3 in 0.4 mg HepG2 whole cell lysate.
      Western blot was performed on the immunoprecipitate using MEK3 Rabbit mAb at 1/1000 dilution.
      Secondary antibody (HRP) for IP was used at 1/400 dilution.
      Lane 1: HepG2 whole cell lysate 20 µg (Input)
      Lane 2: MEK3 Rabbit mAb IP in HepG2 whole cell lysate
      Lane 3: Rabbit monoclonal IgG IP in HepG2 whole cell lysate
      Predicted MW: 39 kDa
      Observed MW: 36, 39 kDa

  • 免疫组化

    • IHC shows positive staining in paraffin-embedded human colon. Anti-MEK3 antibody was used at 1/250 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human skeletal muscle. Anti-MEK3 antibody was used at 1/250 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human breast cancer. Anti-MEK3 antibody was used at 1/250 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded human lung adenocarcinoma. Anti-MEK3 antibody was used at 1/250 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

    • IHC shows positive staining in paraffin-embedded mouse skeletal muscle. Anti-MEK3 antibody was used at 1/250 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.

  • 免疫细胞化学

    • ICC shows positive staining in HepG2 cells. Anti-MEK3 antibody was used at 1/500 dilution (Green) and incubated overnight at 4°C. Goat polyclonal Antibody to Rabbit IgG - H&L (Alexa Fluor® 488) was used as secondary antibody at 1/1000 dilution. The cells were fixed with 4% PFA and permeabilized with 0.1% PBS-Triton X-100. Nuclei were counterstained with DAPI (Blue). Counterstain with tubulin (Red).

    • ICC shows positive staining in NIH/3T3 cells. Anti-MEK3 antibody was used at 1/500 dilution (Green) and incubated overnight at 4°C. Goat polyclonal Antibody to Rabbit IgG - H&L (Alexa Fluor® 488) was used as secondary antibody at 1/1000 dilution. The cells were fixed with 4% PFA and permeabilized with 0.1% PBS-Triton X-100. Nuclei were counterstained with DAPI (Blue). Counterstain with tubulin (Red).

FAQs

斯达特公司的抗体,可以回收利用几次?

我们一般不推荐客户回收利用抗体。 因为抗体使用之后缓冲体系已经发生改变,不同客户在回收抗体的保存条件上也会有差异,所以抗体回收使用效果无法保证。另外,我们对一批抗体回收验证测试,测试结果显示不同抗体可回收次数不同,一般效价越高的抗体,可重复使用的次数越多,客户可根据实验情况来确定

评论(0)