产品介绍 FAQs 评论(0)
宿主来源
Rabbit抗原名称
Synapsin-1分子别名
Brain protein 4.1, Synapsin I, SYN1免疫原
Synthetic PeptideAccession
P17600克隆号
S-550-7抗体类型
Recombinant mAb反应种属 ?
Hu, Ms, Rt预测反应种属
(反应种属缩写表)Bv, Dg纯化方式
Protein A浓度
0.5 mg/ml标记
Unconjugated性状
Liquid缓冲体系
PBS, 40% Glycerol, 0.05%BSA, 0.03% Proclin 300储存条件
12 months from date of receipt / reconstitution, -20 °C as supplied
应用
IHC-P ?
WB
IP
稀释度
应用 稀释度 推荐种属 WB 1:1000 Ms, Rt IP 1:50 Ms IHC 1:2000
The synapsin I protein is a member of the synapsin family that are neuronal phosphoproteins which associate with the cytoplasmic surface of synaptic vesicles. Pathways leading to the induction of human eS6 phosphorylation have been found to enhance IL-8 protein synthesis. This mechanism is dependent on A/U-rich proximal sequences (APS) found in the 3'UTR of IL-8 immediately after the stop codon. Synapsin I plays important roles in synapse formation where they specifically minimize depletion of the neurotransmitter at the inhibitory synapses by contributing to the anchoring of synaptic vesicles.
免疫印迹
WB result of Synapsin-1 Rabbit mAb
Primary antibody: Synapsin-1 Rabbit mAb at 1/1000 dilution
Lane 1: rat brain lysate 20 µg
Secondary antibody: Goat Anti-Rabbit IgG, (H+L), HRP conjugated at 1/10000 dilution
Predicted MW: 74, 70 kDa
Observed MW: 77, 68 kDaWB result of Synapsin-1 Rabbit mAb
Primary antibody: Synapsin-1 Rabbit mAb at 1/1000 dilution
Lane 1: mouse lung lysate 20 µg
Lane 2: mouse brain lysate 20 µg
Negative control: mouse lung lysate
Secondary antibody: Goat Anti-Rabbit IgG, (H+L), HRP conjugated at 1/10000 dilution
Predicted MW: 74, 70 kDa
Observed MW: 77, 68 kDa
免疫沉淀
Synapsin-1 Rabbit mAb at 1/50 dilution (1 µg) immunoprecipitating Synapsin-1 in 0.4 mg mouse brain lysate.
Western blot was performed on the immunoprecipitate using Synapsin-1 Rabbit mAb at 1/1000 dilution.
Secondary antibody (HRP) for IP was used at 1/400 dilution.
Lane 1: mouse brain lysate 20 µg (Input)
Lane 2: Synapsin-1 Rabbit mAb IP in mouse brain lysate
Lane 3: Rabbit monoclonal IgG IP in mouse brain lysate
Predicted MW: 74, 70 kDa
Observed MW: 77,68 kDa
免疫组化
IHC shows positive staining in paraffin-embedded human cerebral cortex. Anti-Synapsin-1 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.
Negative control: IHC shows negative staining in paraffin-embedded human colon. Anti-Synapsin-1 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.
Negative control: IHC shows negative staining in paraffin-embedded human kidney. Anti-Synapsin-1 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.
Negative control: IHC shows negative staining in paraffin-embedded human gastric cancer. Anti-Synapsin-1 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.
IHC shows positive staining in paraffin-embedded mouse cerebral cortex. Anti-Synapsin-1 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.
Negative control: IHC shows negative staining in paraffin-embedded mouse lung. Anti-Synapsin-1 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.
IHC shows positive staining in paraffin-embedded rat cerebral cortex. Anti-Synapsin-1 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.
Negative control: IHC shows negative staining in paraffin-embedded rat spleen. Anti-Synapsin-1 antibody was used at 1/2000 dilution, followed by a HRP Polymer for Mouse & Rabbit IgG (ready to use). Counterstained with hematoxylin. Heat mediated antigen retrieval with Tris/EDTA buffer pH9.0 was performed before commencing with IHC staining protocol.
FAQs
我们一般不推荐客户回收利用抗体。 因为抗体使用之后缓冲体系已经发生改变,不同客户在回收抗体的保存条件上也会有差异,所以抗体回收使用效果无法保证。另外,我们对一批抗体回收验证测试,测试结果显示不同抗体可回收次数不同,一般效价越高的抗体,可重复使用的次数越多,客户可根据实验情况来确定







评论(0)